The explosion-proof outdoor socket VR VZ RN is a connector for connecting mobile equipment by fully connecting it to the explosion-proof plug VR VZ VN and moving it to the “ON” position and is designed for a rated voltage of no more than 690 V DC and AC with a frequency of 50 (60) Hz and a rated current of no more than 125 A.
Explosion-proof connectors, by their design, can be used both in open production areas and in industrial premises engaged in the extraction, processing and transportation of oil and gas, the chemical industry, as well as in mines and pits hazardous due to gas and dust.
| Type of explosion protection | 1Ex de IIC T6…T5 Gb X / Ex tb IIIС T85°C… T100 0 С Db X |
| Body material | Polyamide. |
| Degree of protection of the shell according to GOST 14254-2015 | IP66 |
| Temperature class of equipment | T6 |
| T5 | |
| Ambient temperature under operating conditions | -60°С ≤ Та ≤ 60°С |
| Number of contacts | 2, 3, 4, 5 |
| Nominal voltage in the AC circuit with a frequency of 50 (60) Hz, V | ~220, ~380 |
| Nominal working voltage, V | no more than ~690 |
| Nominal working current, A | 16 (10)*, 32 (20)*, 63 (50, 60)*, 125 (100)* |
| VR | VZ | X 1 / | X 2 / | X 3 | PH | – Y – | Z | U | ||||||||||
| | | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
||||||||||
| | | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| Specified for Ex component.; |
||||||||||
| | | |
| | |
| | |
| | |
| | |
| | |
| | |
| Additional elements (cable entries, plugs, etc.)*; |
|||||||||||
| | | |
| | |
| | |
| | |
| | |
| | |
Case material. (C - low-carbon steel, H - stainless steel). Aluminum alloy is installed by default and is not specified in the marking)*; | ||||||||||||
| | | |
| | |
| | |
| | |
| | |
| "Outdoor socket"; |
|||||||||||||
| | | |
| | |
| | |
| | |
| Number of poles (see Appendix A); |
||||||||||||||
| | | |
| | |
| | |
| Nominal voltage, V (see Appendix A); |
|||||||||||||||
| | | |
| | |
| Nominal current, A 10, 16, 20, 25, 32, 50, 60, 63, 80, 100, 125 (see table No. 2 and note); |
||||||||||||||||
| | | |
| Explosion protection type "e" according to GOST R IEC 60079-7-2012; |
|||||||||||||||||
| | Explosion-proof connector. |
||||||||||||||||||
* May not be indicated in the equipment name.

Appendix A
middle;">−
| Item No. | Nominal working current, A | Nominal working voltage, V | Frequency, Hz | Type | Overall and installation dimensions, mm | |||||
| L | B | H | TO | K 1 | Q | |||||
| 1 | 2 | 3 | 4 | 5 | 6 | |||||
| 1 | 16 (10) | 480~500 | 50/60 | 3P + ⏚ | 236 | 110 | 147 | 135 | 100 | 7 |
| 2 | 380~415 | 3P + N + ⏚ | 236 | 110 | 147 | 135 | 100 | 7 | ||
| 3P + ⏚ | 236 | 110 | 147 | 135 | 100 | 7 | ||||
| 3 | 200~250 | 3P + N + ⏚ | 236 | 110 | 147 | 135 | 100 | 7 | ||
| 3P + ⏚ | 223 | 90 | 138 | 115 | 80 | 7 | ||||
| 2P + ⏚ | ||||||||||
| 4 | 100~130 | 1P + N + ⏚ | 223 | 90 | 138 | 115 | 80 | 7 | ||
| 5 | -36 | - | 2P + ⏚ | 223 | 90 | 138 | 115 | 80 | 7 | |
| 2P | ||||||||||
| 6 | -24 | 2P + ⏚ | 223 | 90 | 138 | 115 | 80 | 7 | ||
| 2P | ||||||||||
| 7 | 32 (20) | 600~690 | 50/60 | 3P + ⏚ | 285 | 120 | 165 | 170 | 110 | 7 |
| 8 | 480~500 | 50/60 | 3P + ⏚ | |||||||
| 9 | 380~415 | 50/60 | 3P + N + ⏚ | |||||||
| 3P + ⏚ | ||||||||||
| 10 | 200~250 | 50/60 | 3P + N + ⏚ | |||||||
| 3P + ⏚ | ||||||||||
| 11 | 63 (50), (60) | 600~690 | 50/60 | 3P + ⏚ | 475 | 200 | 225 | 275 | 185 | 9 |
| 12 | 480~500 | 3P + ⏚ | ||||||||
| 13 | 380~415 | 3P + N + ⏚ | ||||||||
| 3P + ⏚ | ||||||||||
| 14 | 200~250 | 3P + N + ⏚ | ||||||||
| 3P + ⏚ | ||||||||||
| 15 | 125 (100) | 600~690 | 50/60 | 3P + ⏚ | 540 | 235 | 260 | 305 | 218 | 9 |
| 16 | 480~500 | 3P + ⏚ | ||||||||
| 17 | 380~415 | 3P + N + ⏚ | ||||||||
| 3P + ⏚ | ||||||||||
| 18 | 200~250 | 3P + N + ⏚ | ||||||||
| 3P + ⏚ | ||||||||||